Comparison of Four Bowel Cleansing Agents for Colonoscopy and the Factors Affecting their Efficacy. A Prospective, Randomized Study

J Gastrointestin Liver Dis. 2021 Jun 18;30(2):213-220. doi: 10.15403/jgld-3401.

Abstract

Background and aims: Adequate bowel preparation is essential for successful and effective colonoscopy. Several types of cleansing agents are currently available including low-volume solutions. The aim of this study was to compare the efficacy of four different bowel cleansing agents.

Methods: A single-center, prospective, randomized, and single-blind study was performed. Consecutive patients referred for colonoscopy were enrolled and randomized into one of the following types of laxatives: polyethylenglycol 4L (PEG), oral sulfate solution (OSS), 2L polyethylenglycol + ascorbate (2L-PEG/Asc), or magnesium citrate + sodium picosulfate (MCSP). The primary outcome was quality of bowel cleansing evaluated according to the Boston Bowel Preparation Scale (BBPS). Secondary outcomes were polyp detection rate (PDR) and tolerability.

Results: Final analysis was performed on 431 patients. The number of patients with adequate bowel preparation (BBPS total scores ≥6 and sub scores ≥2 in each segment) was not significantly different throughout all groups (95.4% PEG; 94.6% OSS; 96.3% 2L-PEG/Asc; 96.2% MCSP; p=0.955). Excellent bowel preparation (BBPS total scores ≥ 8) was associated with younger age (p=0.007). The groups did not have significantly different PDRs (49.5% PEG; 49.1% OSS; 38% 2L-PEG/Asc; 40.4% MCSP; p=0.201). The strongest predictors of pathology identification were age and male gender. The best-tolerated solution was MCSP (palatability: p<0.001; nausea: p=0.024).

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Cathartics* / adverse effects
  • Colonoscopy
  • Detergents*
  • Humans
  • Male
  • Polyethylene Glycols / adverse effects
  • Prospective Studies
  • Single-Blind Method

Substances

  • Cathartics
  • Detergents
  • Polyethylene Glycols