Design of a Real-Time Salinity Detection System for Water Injection Wells Based on Fuzzy Control

Sensors (Basel). 2021 Apr 28;21(9):3086. doi: 10.3390/s21093086.

Abstract

Salinity is an important index of water quality in oilfield water injection engineering. To address the need for real-time measurement of salinity in water flooding solutions during oilfield water injection, a salinity measurement system that can withstand a high temperature environment was designed. In terms of the polarization and capacitance effects, the system uses an integrator circuit to collect information and fuzzy control to switch gears to expand the range. Experimental results show that the system can operate stably in a high-temperature environment, with an accuracy of 0.6% and an uncertainty of 0.2% in the measurement range of 1-10 g/L.

Keywords: conductivity; fuzzy control; integrator circuit; salinity.