Cementless total hip arthroplasty for failed treatment of subtrochanteric fracture

BMC Musculoskelet Disord. 2021 Apr 24;22(1):384. doi: 10.1186/s12891-021-04268-8.

Abstract

Background: Failed treatment of subtrochanteric fractures commonly leads to pain, limping, and poor limb function. Cementless total hip arthroplasty (THA) could serve as an efficient salvage procedure in such cases. This study aimed to evaluate the outcomes and complications of salvage THA in failed subtrochanteric fracture fixation cases.

Methods: From January 2001 to December 2017, cementless THA for failed treatment of subtrochanteric fractures was performed in 18 hips of 11 men and 7 women (average age, 74 years; age range, 57.0-89.0 years). Patients were followed up for clinical and radiological assessments in terms of implant survival and complications after a minimum follow-up of 2 years. The Wagner femoral stems (Zimmer, Warsaw, USA) were used in all 18 patients (100%), with the long-length stem (Wagner SL stem) and standard-length stem (Wagner cone stem) used in 11 and 7 patients, respectively.

Results: The mean follow-up period was 5.2 years (range: 2.2-10.8 years). The mean Harris hip score (HHS) was 38.2 (range: 24-56) preoperatively and 85.4 (range: 79-92) at the last follow-up. The mean postoperative limb length discrepancy was 6.4 mm (range: 4-9 mm). Only one patient underwent revision due to bone in-growth failure of the femoral stem. One patient had an episode of postoperative dislocation and was treated with closed reduction without reoccurrence. Delayed union of the fracture site occurred in one patient. Patients who were previously treated with an intramedullary nail had a significantly shorter surgical duration, lesser intraoperative blood loss, and fewer blood transfusions than those who were previously treated with plate and screws. Kaplan-Meier survival rate with an endpoint of revision was 94.4% (95% confidence interval 72.7-99.9) at 5 years.

Conclusion: Our results indicate that cementless THA is a beneficial and effective procedure for salvaging the failed treatment of subtrochanteric fractures. The Wagner conical prosthesis has shown satisfactory function outcomes, stable fixation, and survival rate for these complex situations. However, attention should be paid to increased operation time, blood loss, and complications when performing THA for subtrochanteric fractures with failed fixation devices especially, plates and screws.

Keywords: Cementless total hip arthroplasty; Complication; Failed treatment; Subtrochanteric fracture; Taper stem.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Hip* / adverse effects
  • Female
  • Femur / surgery
  • Follow-Up Studies
  • Hip Fractures* / diagnostic imaging
  • Hip Fractures* / surgery
  • Hip Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Reoperation
  • Retrospective Studies
  • Treatment Outcome