Correlations Between Dark-Adapted Rod Threshold Elevations and ERG Response Deficits in Duchenne Muscular Dystrophy

Invest Ophthalmol Vis Sci. 2021 Apr 1;62(4):29. doi: 10.1167/iovs.62.4.29.

Abstract

Purpose: The purpose of this study was to characterize changes in the full-field flash electroretinogram (ERG) in association with psychophysical dark-adapted visual thresholds in patients with genetically characterized Duchenne muscular dystrophy (DMD) either lacking Dp427 (Up 30) or at least Dp260 in addition to Dp427 (Down 30).

Methods: Twenty-one patients with DMD and 27 age-similar controls participated in this study. Dark-adapted (0.01, 3.0, and 10 cd.s/m² flashes) and light-adapted (3.0 cd.s/m² flash) ERGs were recorded following International Society for Clinical Electrophysiology of Vision (ISCEV) standard protocols. Visual detection thresholds to 625-nm (cone function) and 527-nm (rod function) light-emitting diode (LED) flashes (2 degree diameter) were measured during a dark adaptation period after a 1-minute exposure to a bleaching light (3000 cd/m²). Initially, 8 minutes of interleaved 625-nm and 527-nm thresholds were measured. After an additional 5 minutes of dark-adaptation, a second set of threshold measurements to 527-nm stimuli was performed during the subsequent 6 minutes.

Results: Dark-adapted b-wave amplitude was significantly reduced to all strengths of flash and a-wave in response to the strong flash stimulus was delayed (15.6 vs. 14.7 ms, P < 0.05) in patients with Down 30 compared with controls. Dark-adapted cone thresholds did not differ among the groups (-2.0, -1.8, and -1.7 log cd/m² for Down 30, Up 30, and controls, respectively, P = 0.21). In contrast, dark-adapted rod thresholds were elevated (F(2,36) = 8.537, P = 0.001) in patients with Down 30 (mean = -3.2 ± 1.1 log cd/m²) relative to controls (mean = -4.2 ± 0.3 log cd/m²). Dark-adapted b-wave amplitudes were correlated with dark-adapted rod sensitivity in patients with DMD (Spearman Rho = 0.943, P = 0.005). The changes were much smaller or absent in patients with intact Dp260.

Conclusions: Dp260 is particularly required for normal rod-system function in dark adaptation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Child
  • Dark Adaptation / physiology*
  • Electroretinography / methods*
  • Female
  • Humans
  • Male
  • Muscular Dystrophy, Duchenne / pathology
  • Muscular Dystrophy, Duchenne / physiopathology*
  • Photic Stimulation
  • Retinal Cone Photoreceptor Cells / metabolism*
  • Retinal Cone Photoreceptor Cells / pathology
  • Sensory Thresholds / physiology*
  • Visual Perception / physiology*
  • Young Adult