Stent Graft Oversizing is Associated with an Increased Risk of Long-Term Left Ventricular Wall Thickening in Young Patients Following Thoracic Endovascular Aortic Repair

Ann Vasc Surg. 2021 Oct:76:66-72. doi: 10.1016/j.avsg.2021.02.029. Epub 2021 Apr 8.

Abstract

Background: Left ventricular (LV) wall thickening occurs in patients following thoracic endovascular aortic repair (TEVAR). Clinical consequences of cardiovascular (CV) remodeling may be more significant younger patients with longer anticipated life spans. Risk factors for CV remodeling following TEVAR are unknown but may be related to graft size.

Methods: A retrospective analysis was performed of a multicenter healthcare system including patients aged ≤60 who underwent TEVAR between 2011 and 2019 with at least 1 year follow-up computed tomography angiography imaging available. Standard perioperative variables, native aortic diameter, and stent graft specifications were collected. Graft oversizing was calculated by dividing proximal graft diameter by proximal aortic diameter on preoperative imaging. Posterior LV wall thickness was measured at baseline and interval increases were normalized to time-to-follow-up. Primary outcome was annual rate of posterior LV wall thickening.

Results: One hundred one patients met inclusion criteria with a mean (SD) follow-up time of 1270 (693) days. Overall mean (SD) rate of LV wall thickness change was 0.534 (0.750) mm per year. Mean (SD) absolute LV wall thickness at most recent follow-up was 10.97 (2.85) mm for men, 9.69 (2.03) mm for women. Multivariate analysis demonstrated that higher rates of LV wall thickening were associated with narrower graft diameters (P = 0.0311). Greater absolute LV wall thickness at follow-up was associated with narrower grafts (P= 0.0155) and greater graft oversizing (P= 0.0376). Logistic regression demonstrated individuals who met criteria for LV hypertrophy were more likely to have narrower stent-grafts (P= 0.00798) and greater graft oversizing (P= 0.0315).

Conclusions: LV wall thickening occurred to a greater degree in individuals with narrower stent-grafts and higher rates of graft oversizing. This has significant implications for long-term cardiovascular health in younger patients may undergo TEVAR for atypical indications. Particular attention should be paid to long-term effects of stent-graft oversizing when selecting grafts in such populations.

MeSH terms

  • Adult
  • Age Factors
  • Aorta, Thoracic / diagnostic imaging
  • Aorta, Thoracic / surgery*
  • Aortic Diseases / diagnostic imaging
  • Aortic Diseases / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Female
  • Humans
  • Hypertrophy, Left Ventricular / diagnostic imaging
  • Hypertrophy, Left Ventricular / etiology*
  • Hypertrophy, Left Ventricular / physiopathology
  • Male
  • Middle Aged
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stents*
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Left*
  • Ventricular Remodeling*