To improve the removal efficiency of dissolved organic matter in wastewater treatment plant (WWTP) effluent, electro-hybrid ozonation-coagulation (E-HOC) is proposed and the treatment characteristics and removal mechanism for WWTP effluent and ibuprofen (IBP) are investigated. The E-HOC process has a better removal effect on dissolved organic matter in WWTP effluent, achieving 46.4%, 20.0%, 19.4%, 36.1%, and 49.7% higher removal than EC, ozonation, pre-ozonation-EC, electrocoagulation-ozonation, and chemical coagulation, respectively. To determine the mechanism of the E-HOC process, quenching experiments and electron paramagnetic resonance (EPR) were conducted, which confirmed that metal coagulants can be used as a catalyst to effectively increase the generation of the hydroxyl radical (·OH). Synergistic effects between ozone and the coagulants (SOC) were also found to be involved. Fourier-transform infrared spectroscopy (FT-IR) illustrated that the surface hydroxyl groups of the coagulant (hydrolyzed species produced by Al anode electrolysis) were the active sites for the generation of·OH in the SOC reaction. Based on a kinetics analysis of organic matter removal in the E-HOC system, SOC effects and ozonation played dominant roles in the E-HOC process. Additionally, the SOC created a new pathway for·OH formation.

Keywords: electro-hybrid ozonation-coagulation (E-HOC); electrocoagulation; ozonation; surface hydroxyl groups; synergistic effects.