FULL-THICKNESS MACULAR HOLE SIZE BY HYPERTRANSMISSION SIGNAL ON SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY

Retina. 2021 Oct 1;41(10):2059-2065. doi: 10.1097/IAE.0000000000003163.

Abstract

Purpose: To assess the full-thickness macular hole (FTMH) size using the choroidal hypertransmission signal on spectral-domain optical coherence tomography and to compare this method to the standard aperture measurement of the minimum aperture size at the level of the neurosensory retina.

Design: Cross-sectional study of retrospective data.

Methods: Eyes with FTMH imaged on spectral-domain optical coherence tomography were included. Two independent masked graders used the device's built-in caliper tool to measure the FTMH minimum aperture size at the level of the neurosensory retina and the size of the corresponding hypertransmission signal below the level of the retinal pigment epithelium/Bruch membrane complex. To assess the reproducibility of the hypertransmission measurement in tilted scans, two measurements were obtained and compared; the first was traced parallel to the retinal pigment epithelium (parallel hypertransmission), and the second was horizontal to the image frame (horizontal hypertransmission), both using Image J software.

Results: A total of 31 eyes were enrolled. The mean FTMH minimum aperture size was smaller compared with both the choroidal parallel hypertransmission and horizontal hypertransmission measurements (mean ± SD: 335.7 ± 139.5 µm, 376.7 ± 150.6 µm, 375.1 ± 150.0 µm, respectively. P < 0.001 for both comparisons).

Conclusion: The proposed hypertransmission measurement is a feasible and reproducible alternative to assess FTMH size and could provide the basis for an automated FTMH measurement on cross-sectional spectral-domain optical coherence tomography scans, as presented in this study, or on the spectral-domain optical coherence tomography volumetric data set by using an en face projection.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Choroid / diagnostic imaging*
  • Cross-Sectional Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Retinal Perforations / diagnostic imaging*
  • Retinal Perforations / pathology
  • Retinal Pigment Epithelium / diagnostic imaging
  • Retrospective Studies
  • Tomography, Optical Coherence*
  • Visual Acuity