Offline comparison of processed electroencephalogram monitors for anaesthetic-induced electroencephalogram changes in older adults

Br J Anaesth. 2021 May;126(5):975-984. doi: 10.1016/j.bja.2020.12.042. Epub 2021 Feb 25.

Abstract

Background: Several devices record and interpret patient brain activity via electroencephalogram (EEG) to aid physician assessment of anaesthetic effect. Few studies have compared EEG monitors on data from the same patient. Here, we describe a set-up to simultaneously compare the performance of three processed EEG monitors using pre-recorded EEG signals from older surgical patients.

Methods: A playback system was designed to replay EEG signals into three different commercially available EEG monitors. We could then simultaneously calculate indices from the SedLine® Root (Masimo Inc., Irvine, CA, USA; patient state index [PSI]), bilateral BIS VISTA™ (Medtronic Inc., Minneapolis, MN, USA; bispectral index [BIS]), and Datex Ohmeda S/5 monitor with the Entropy™ Module (GE Healthcare, Chicago, IL, USA; E-entropy index [Entropy]). We tested the ability of each system to distinguish activity before anaesthesia administration (pre-med) and before/after loss of responsiveness (LOR), and to detect suppression incidences in EEG recorded from older surgical patients receiving beta-adrenergic blockers. We show examples of processed EEG monitor output tested on 29 EEG recordings from older surgical patients.

Results: All monitors showed significantly different indices and high effect sizes between comparisons pre-med to after LOR and before/after LOR. Both PSI and BIS showed the highest percentage of deeply anaesthetised indices during periods with suppression ratios (SRs) > 25%. We observed significant negative correlations between percentage of suppression and indices for all monitors (at SR >5%).

Conclusions: All monitors distinguished EEG changes occurring before anaesthesia administration and during LOR. The PSI and BIS best detected suppressed periods. Our results suggest that the PSI and BIS monitors might be preferable for older patients with risk factors for intraoperative awareness or increased sensitivity to anaesthesia.

Keywords: EEG; bispectral index (BIS); brain monitoring; entropy; patient state index (PSI); processed EEG.

Publication types

  • Comparative Study

MeSH terms

  • Adrenergic beta-Antagonists / pharmacology*
  • Aged
  • Aged, 80 and over
  • Anesthetics / pharmacology*
  • Consciousness Monitors
  • Electroencephalography / instrumentation*
  • Female
  • Humans
  • Male
  • Monitoring, Intraoperative / instrumentation
  • Monitoring, Intraoperative / methods*
  • Risk Factors

Substances

  • Adrenergic beta-Antagonists
  • Anesthetics