Thermal plasma activation and UV/H2O2 oxidative degradation of pharmaceutical residues

Environ Res. 2021 Apr:195:110884. doi: 10.1016/j.envres.2021.110884. Epub 2021 Feb 22.

Abstract

The aquatic environment becomes increasingly contaminated by anthropogenic pollutants such as pharmaceutical residues. Due to poor biodegradation and continuous discharge of persistent compounds in sewage water samples, pharmaceutical residues might end up in surface waters when not removed. To minimize this pollution, onsite wastewater treatment techniques might complement conventional waste water treatment plants (WWTPs). Advanced oxidation processes are useful techniques, since reactive oxygen species (ROS) are used for the degradation of unwanted medicine residues. In this paper we have studied the advanced oxidation in a controlled laboratory setting using thermal plasma and UV/H2O2 treatment. Five different matrices, Milli-Q water, tap water, synthetic urine, diluted urine and synthetic sewage water were spiked with 14 pharmaceuticals with a concentration of 5 μg/L. All compounds were reduced or completely decomposed by both 150 W thermal plasma and UV/H2O2 treatment. Additionally, also hospital sewage water was tested. First the concentrations of 10 pharmaceutical residues were determined by liquid chromatography mass spectrometry (LC-MS/MS). The pharmaceutical concentration ranged from 0.08 up to 2400 μg/L. With the application of 150 W thermal plasma or UV/H2O2, it was found that overall pharmaceutical degradation in hospital sewage water were nearly equivalent to the results obtained in the synthetic sewage water. However, based on the chemical abatement kinetics it was demonstrated that the degree of degradation decreases with increasing matrix complexity. Since reactive oxygen and nitrogen species (RONS) are continuously produced, thermal plasma treatment has the advantage over UV/H2O2 treatment.

Keywords: Advanced oxidation processes; Complex water matrices; Hospital sewage water; Medicine residues.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, Liquid
  • Hydrogen Peroxide
  • Oxidation-Reduction
  • Oxidative Stress
  • Pharmaceutical Preparations*
  • Plasma Gases*
  • Tandem Mass Spectrometry
  • Ultraviolet Rays
  • Wastewater
  • Water Pollutants, Chemical* / analysis
  • Water Purification*

Substances

  • Pharmaceutical Preparations
  • Plasma Gases
  • Waste Water
  • Water Pollutants, Chemical
  • Hydrogen Peroxide