Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values

Br J Radiol. 2021 May 1;94(1121):20200869. doi: 10.1259/bjr.20200869. Epub 2021 Feb 17.

Abstract

Objectives: Diffusion-weighted imaging (DWI) plays a crucial role in the diagnosis of ischemic stroke. We assessed the value of computed and acquired high b-value DWI in comparison with conventional b = 1000 s mm-2 DWI for ischemic stroke at 3T.

Methods: We included 36 patients with acute ischemic stroke who presented with diffusion abnormalities on DWI performed within 24 h of symptom onset. B-values of 0, 500, 1000 and 2000 s mm-2 were acquired. Synthetic images with b-values of 1000, 1500, 2000 and 2500 s mm-2 were computed. Two readers compared synthetic (syn) and acquired (acq) b = 2000 s mm-2 images with acquired b = 1000 s mm-2 images in terms of lesion detection rate, image quality, presence of uncertain hyperintensities and lesion conspicuity. Readers also selected their preferred b-value. Contrast ratio (CR) measurements were performed. Non-parametrical statistical tests and weighted Cohens' κ tests were computed.

Results: Syn1000 and syn1500 matched acq1000 images in terms of lesion detection rate, image quality and presence of uncertain hyperintensities but presented with significantly improved lesion conspicuity (p < 0.01) and were frequently selected as preferred b-values. Acq2000 images exhibited a similar lesion detection rate and improved lesion conspicuity (p < 0.01) but worse image quality (p < 0.01) than acq1000 images. Syn2000 and syn2500 images performed significantly worse (p < 0.01) than acq1000 images in most or all categories. CR significantly increased with increasing b-values.

Conclusion: Synthetic images at b = 1000 and 1500 s mm-2 and acquired DWI images at b = 2000 s mm-2 may be of clinical value due to improved lesion conspicuity.

Advances in knowledge: Synthetic b-values enable improved lesion conspicuity for DWI of ischemic stroke.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Diffusion Magnetic Resonance Imaging / methods*
  • Diffusion Magnetic Resonance Imaging / standards
  • Female
  • Humans
  • Ischemic Stroke / diagnostic imaging*
  • Male
  • Middle Aged
  • Reference Standards
  • Retrospective Studies
  • Signal-To-Noise Ratio
  • Uncertainty