Tacrolimus Measured in Capillary Volumetric Microsamples in Pediatric Patients-A Cross-Validation Study

Ther Drug Monit. 2021 Jun 1;43(3):371-375. doi: 10.1097/FTD.0000000000000873.

Abstract

Background: Therapeutic drug monitoring of tacrolimus (Tac) is mandatory in solid organ transplant (SOT) recipients. Finger-prick microsampling is more flexible and tolerable during the therapeutic drug monitoring of tacrolimus and has been shown to be applicable in adult SOT recipients. In this study, a previously validated method applying volumetric absorptive microsampling (VAMS) to measure Tac in adults was cross-validated in a pediatric population.

Methods: Patients with SOT scheduled for standard posttransplant follow-up visits were recruited. Blood samples were obtained by trained phlebotomists using standard venipuncture and capillary microsampling, before the morning dose of Tac as well as 2 and 5 hours after dosing. Tac concentrations were quantified using liquid chromatography-tandem mass spectrometry. Concordance between Tac concentrations obtained with venipuncture and VAMS was evaluated using Passing-Bablok regression, calculation of absolute and relative differences, and percentage of samples within ±20% and ±30% difference.

Results: A total of 39 SOT patients aged 4-18 years (22 male) were included. The median (range) predose venous blood concentration was 4.8 (2.6-13.6) mcg/L, with a difference between VAMS and venous blood samples of -0.2 ± 0.7 mcg/L. The relative mean difference was -1.3% [95% confidence interval (CI), -5.9% to 3.4%]. Ninety-two percent and 97% of the sample pairs demonstrated differences within ±20% and ±30%, respectively. Postdose (2 hours and/or 5 hours, n = 17) median concentration in venous blood was 7.9 (4.8-19.2) mcg/L. The difference between VAMS and venous blood samples was 0.1 ± 1.0 mcg/L, with a relative mean difference of -2.5% (95% confidence interval, -8.8% to 3.8%). Eighty-eight percent of the postdose sample pairs were within ±20% difference, and all were within ±30% difference.

Conclusions: Tac concentrations can be accurately measured using VAMS technology in pediatric SOT recipients. This makes home-based Tac monitoring feasible in the pediatric population.

Publication types

  • Validation Study

MeSH terms

  • Adolescent
  • Blood Specimen Collection*
  • Child
  • Child, Preschool
  • Chromatography, Liquid
  • Drug Monitoring*
  • Female
  • Humans
  • Male
  • Tacrolimus* / pharmacokinetics
  • Transplant Recipients

Substances

  • Tacrolimus