Dural rupture and subsequent spinal cord herniation due to closed wound suction drainage after spinal surgery

Br J Neurosurg. 2023 Oct;37(5):1171-1175. doi: 10.1080/02688697.2021.1885623. Epub 2021 Feb 12.

Abstract

Closed wound suction drains are commonly used in spinal surgery. Severe neurological complications related to their use are rare. Here, we report a case of a dural rupture and subsequent spinal cord herniation related to the use of closed suction drains after posterior decompression and fixation surgery for spinal metastasis.

Keywords: Drainage; postoperative complications; spinal cord; spine; surgery.

Publication types

  • Case Reports

MeSH terms

  • Drainage*
  • Female
  • Humans
  • Middle Aged
  • Neurosurgical Procedures*
  • Spinal Cord
  • Suction