Abstract

In this work we present the results of a functional properties assessment via Atomic Force Microscopy (AFM)-based surface morphology, surface roughness, nano-scratch tests and adhesion force maps of TiZr-based nanotubular structures. The nanostructures have been electrochemically prepared in a glycerin + 15 vol.% H2O + 0.2 M NH4F electrolyte. The AFM topography images confirmed the successful preparation of the nanotubular coatings. The Root Mean Square (RMS) and average (Ra) roughness parameters increased after anodizing, while the mean adhesion force value decreased. The prepared nanocoatings exhibited a smaller mean scratch hardness value compared to the un-coated TiZr. However, the mean hardness (H) values of the coatings highlight their potential in having reliable mechanical resistances, which along with the significant increase of the surface roughness parameters, which could help in improving the osseointegration, and also with the important decrease of the mean adhesion force, which could lead to a reduction in bacterial adhesion, are providing the nanostructures with a great potential to be used as a better alternative for Ti implants in dentistry.

Keywords: TiZr nanotubes; force adhesion map; hardness; nano-scratch testing; surface roughness.

MeSH terms

  • Coated Materials, Biocompatible / chemistry*
  • Hardness
  • Materials Testing
  • Mechanical Phenomena
  • Microscopy, Atomic Force
  • Nanostructures / chemistry*
  • Prostheses and Implants*
  • Surface Properties
  • Titanium / chemistry*
  • Zirconium / chemistry*

Substances

  • Coated Materials, Biocompatible
  • Zirconium
  • Titanium