Evaluation of the Accelerate Pheno System for Rapid Identification and Antimicrobial Susceptibility Testing of Positive Blood Culture Bottles Inoculated with Primary Sterile Specimens from Patients with Suspected Severe Infections

J Clin Microbiol. 2021 Apr 20;59(5):e02637-20. doi: 10.1128/JCM.02637-20. Print 2021 Apr 20.

Abstract

The Accelerate Pheno system is approved for rapid identification and phenotypic antimicrobial susceptibility testing (AST) of microorganisms grown from positive blood cultures inoculated with blood from septic patients. We evaluated the performance of the system for identification and AST from positive blood culture bottles inoculated with primary sterile nonblood specimens from patients with suspected severe infections. One hundred positive blood culture bottles with primary sterile specimens (63 cerebrospinal fluids, 16 ascites, 7 pleural fluids, 4 vitreous fluids, 5 joint aspirates, and 5 other aspirates) from 100 patients were included. Pathogen identification was in agreement with conventional methods for 72 of 100 cultures (72%) and for 81 of 112 (72%) pathogens when considering all pathogens and for 72 of 92 (78%) cultures and 81 of 104 (78%) pathogens when considering on-panel pathogens only. Eight of 31 isolates (26%) not identified by APS were pathogens not included in the APS panel. APS and conventional methods accordingly identified all pathogens from two of nine polymicrobial cultures (22%). APS generated antimicrobial resistance results for 57 pathogens of 57 cultures. The overall category agreement between APS and culture-based AST was 91.2%; and the rate for minor errors was 6.9%, for major was 1.7%, and for very major errors was 0.2%. APS may accelerate pathogen identification and phenotypic AST from positive blood culture bottles inoculated with primary sterile specimens from patients with serious infections, especially for hospitals without an on-site microbiology laboratory. However, the inclusion of nonblood specimens with a high likelihood of polymicrobial infections may result in an inferior performance.

Keywords: bacterial identification; blood culture; primary sterile specimens; rapid tests; susceptibility.

MeSH terms

  • Anti-Bacterial Agents / pharmacology
  • Anti-Bacterial Agents / therapeutic use
  • Anti-Infective Agents*
  • Bacteremia* / diagnosis
  • Bacteremia* / drug therapy
  • Blood Culture
  • Humans
  • Microbial Sensitivity Tests
  • Time Factors

Substances

  • Anti-Bacterial Agents
  • Anti-Infective Agents