Determining the parameter space for effective oxygen depletion for FLASH radiation therapy

Phys Med Biol. 2021 Feb 25;66(5):055020. doi: 10.1088/1361-6560/abe2ea.

Abstract

There has been a recent revival of interest in the FLASH effect, after experiments have shown normal tissue sparing capabilities of ultra-high-dose-rate radiation with no compromise on tumour growth restraint. A model has been developed to investigate the relative importance of a number of fundamental parameters considered to be involved in the oxygen depletion paradigm of induced radioresistance. An example eight-dimensional parameter space demonstrates the conditions under which radiation may induce sufficient depletion of oxygen for a diffusion-limited hypoxic cellular response. Initial results support experimental evidence that FLASH sparing is only achieved for dose rates on the order of tens of Gy s-1or higher, for a sufficiently high dose, and only for tissue that is slightly hypoxic at the time of radiation. We show that the FLASH effect is the result of a number of biological, radiochemical and delivery parameters. Also, the threshold dose for a FLASH effect occurring would be more prominent when the parameterisation was optimised to produce the maximum effect. The model provides a framework for further FLASH-related investigation and experimental design. An understanding of the mechanistic interactions producing an optimised FLASH effect is essential for its translation into clinical practice.

Keywords: FLASH radiotherapy; dose rate; oxygen depletion.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Neoplasms* / radiotherapy
  • Oxygen*
  • Radiotherapy Dosage

Substances

  • Oxygen