Characterization of clogging deposits in an irrigation pipeline and effect of post-aeration on clogging potential of tertiary-treated wastewater

Water Sci Technol. 2021 Jan;83(2):309-321. doi: 10.2166/wst.2020.552.

Abstract

In Agadir, a water-scarce Moroccan region, municipal and industrial wastewater is tertiary-treated to be reused in golf courses. Wastewater reuse has been constrained by severe clogging of emitters, which caused technical and financial problems. This study aimed to perform an in-depth characterization of the treated wastewater (TWW) in relation to its susceptibility to cause clogging, and to assess the capacity of an aeration post-treatment to reduce the clogging potential. The post-treatment consisted of injecting different airflows (0-33 L/(h Lreactor) into the TWW. The structural, morphological and elemental composition of the clogging matter collected in the irrigation pipeline was characterized using scanning electron microscopy, scanning transmission electron microscopy, X-ray diffraction and X-ray energy dispersive spectroscopy. The 15-day aeration post-treatment at 16.5 L/(h Lreactor) presented the best cost-benefit ratio. Organic matter was totally degraded. Calcium was reduced by 9%, bicarbonates by 54%. The analysis of the deposits induced by the aeration post-treatment revealed a relevant decrease of the major constituents of the clogging deposits found in the irrigation pipeline. The results show the effectiveness of post-aeration in biodegrading residual organic matter and precipitating several salts, thus reducing the clogging potential.

MeSH terms

  • Agricultural Irrigation*
  • Wastewater*

Substances

  • Waste Water