Spatial and dosimetric evaluation of residual distortions of prostate and seminal vesicle bed after image-guided definitive and postoperative radiotherapy of prostate cancer with endorectal balloon

J Appl Clin Med Phys. 2021 Jan;22(1):226-241. doi: 10.1002/acm2.13138. Epub 2020 Dec 30.

Abstract

Purpose: To quantify daily residual deviations from the planned geometry after image-guided prostate radiotherapy with endorectal balloon and to evaluate their effect on the delivered dose distribution.

Methods: Daily kV-CBCT imaging was used for online setup-correction in six degrees of freedom (6-dof) for 24 patients receiving definitive (12 RTdef patients) or postoperative (12 RTpostop patients) radiotherapy with endorectal balloon (overall 739 CBCTs). Residual deviations were evaluated using several spatial and dosimetric variables, including: (a) posterior Hausdorff distance HDpost (=maximum distance between planned and daily CTV contour), (b) point Pworst with largest HDpost over all fractions, (c) equivalent uniform dose using a cell survival model (EUDSF ) and the generalized EUD concept (gEUDa with parameter a = -7 and a = -20). EUD values were determined for planned ( EUD SF plan ), daily ( EUD SF ind ), and delivered dose distributions ( EUD SF accum ) for plans with 6 mm (=clinical plans) and 2 mm CTV-to-PTV margin. Time series analyses of interfractional spatial and dosimetric deviations were conducted.

Results: Large HDpost values ≥ 12.5 mm (≥15 mm) were observed in 20/739 (5/739) fractions distributed across 7 (3) patients. Points Pworst were predominantly located at the posterior CTV boundary in the seminal vesicle region (16/24 patients, 6/7 patients with HDpost ≥ 12.5 mm). Time series analyses revealed a stationary white noise characteristic of HDpost and relative dose at Pworst . The EUDSF difference between planned and accumulated dose distributions was < 5.4% for all 6-mm plans. Evaluating 2-mm plans, EUDSF deteriorated by < 10% (<5%) in 75% (58.5%) of the patients. EUD SF accum was well described by the median value of the EUD SF ind distribution. PTV margin calculation at Pworst yielded 8.8 mm.

Conclusions: Accumulated dose distributions in prostate radiotherapy with endorectal balloon are forgiving of considerable residual distortions after 6-dof patient setup if they are observed in a minority of fractions and the median value of EUD SF ind determined per fraction stays within 95% of prescribed dose. Common PTV margin calculations are overly conservative because after online correction of translational and rotational errors only residual deformations need to be included. These results provide guidelines regarding online navigation, margin optimization, and treatment adaptation strategies.

Keywords: accumulated dose distributions; image-guided radiotherapy; prostate cancer; residual distortions; time series.

MeSH terms

  • Humans
  • Male
  • Prostatic Neoplasms* / diagnostic imaging
  • Prostatic Neoplasms* / radiotherapy
  • Prostatic Neoplasms* / surgery
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy, Image-Guided*
  • Radiotherapy, Intensity-Modulated*
  • Seminal Vesicles / diagnostic imaging