We report three cases of clinically necessary, fluoroscopy-guided, percutaneous biliary procedures performed safely in a pregnant, liver transplant recipient using three different angiography suites. The uterine cumulative equivalent dose was 0.25 mSv, a value obtained by adding the doses of the three procedures described above, and which is relatively low when compared with the naturally occurring background radiation exposure for a 9-month pregnancy (~0.5-1 mSv). Our experience shows that staff knowledge, awareness and liaison promote the application of all dose reduction strategies possible while still achieving the clinical aim despite using different angiographic equipment.