A Microfluidic Device for Modulation of Organellar Heterogeneity in Live Single Cells

Anal Sci. 2021 Mar 10;37(3):499-503. doi: 10.2116/analsci.20SCP11. Epub 2020 Dec 4.

Abstract

The quantitatively controlled organellar transfer between living single cells provides a unique experimental platform to analyze the contribution of organellar heterogeneity on cellular phenotypes. We previously developed a microfluidic device which can perform quantitatively controlled mitochondrial transfer between live single cells by promoting strictured cytoplasmic connections between live single cells, but its application to other organelles is unclear. In this study, we investigated the quantitative properties of peroxisome transfer in our microfluidic device. When cells were fused through a 10 or 4 μm long microtunnel by a Sendai virus envelope-based method, a strictured cytoplasmic connection was achieved with a length corresponding to that of the microtunnel, and a subsequent recovery culture disconnected the fused cells. The peroxisome number being transferred through a 10 μm length of the microtunnel was smaller than that of 4 μm. These data suggest that our microfuidic device can perform a quantitative control of peroxisome transfer.

Keywords: Microfluidic device; cell fusion; mitochondria; organellar transfer; peroxisome.

MeSH terms

  • Animals
  • Cell Fusion
  • Lab-On-A-Chip Devices*
  • Mice
  • NIH 3T3 Cells
  • Organelles / chemistry*
  • Single-Cell Analysis*