Biomarker discrimination and calibration with MRI-targeted biopsies: an analysis with the Stockholm3 test

Prostate Cancer Prostatic Dis. 2021 Jun;24(2):457-464. doi: 10.1038/s41391-020-00297-x. Epub 2020 Nov 9.

Abstract

Background: The validated Stockholm3 test is used to improve PC detection. Stockholm3, however, was developed using systematic biopsies. We aimed to assess Stockholm3 operating performance when using MRI-targeted biopsies for PC detection.

Methods: A prospective cohort of 532 men was considered for prostate biopsy during 2016-2017. All men underwent Stockholm3 testing and MRI before biopsy. All PIRADs ≥3 lesion underwent targeted biopsy; all men underwent systematic biopsy. The primary outcome was ISUP Grade Group ≥2 (GG ≥ 2) PC. Detection strategies included: (1) systematic biopsies alone, (2) targeted biopsies alone, (3) targeted with associated systematic biopsies for MRI+, and (4) all biopsies in all men. For each strategy, the Stockholm3 operating characteristics were assessed with discrimination, calibration, and decision curve analysis (DCA).

Results: Median age was 65 years, median PSA was 6.2 ng/mL, median Stockholm3 score was 16.5%, and overall detection of GG ≥ 2 PC was 36% (193/532). Stockholm3 showed accurate discrimination for separating GG ≥ 2 cancer from benign and GG1, with an area under the curve of 0.84-0.86 depending on the biopsy strategy. Calibration analysis showed that Stockholm3 underestimated risks for GG ≥ 2 PC risk using MRI-targeted biopsies: there was a net benefit over biopsies in all men for Stockholm3 at risk thresholds varying from >3% in systematic biopsies to >15% in targeted with systematic biopsies in MRI+ men. When using a Stockholm3 score of >10% cutoff, a range of 32-38% of biopsies could be avoided while missing 5-11% of GG ≥ 2 PC and 0-3% of GG ≥ 3 PC.

Conclusions: Stockholm3 shows high discriminatory performance in an MRI-targeted biopsy setting, however risks are underpredicted due to MRI-targeted biopsies being more sensitive than the systematic biopsies for which Stockholm3 was developed. Stockholm3, along with any risk prediction model developed for systematic prostate biopsy decisions, will need recalibration for optimal use in an MRI-driven biopsy setting.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Biomarkers, Tumor / metabolism*
  • Calibration
  • Follow-Up Studies
  • Humans
  • Image-Guided Biopsy / methods*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Prognosis
  • Prospective Studies
  • Prostate-Specific Antigen / metabolism
  • Prostatic Neoplasms / metabolism
  • Prostatic Neoplasms / pathology*
  • Prostatic Neoplasms / surgery
  • Risk Assessment / methods*

Substances

  • Biomarkers, Tumor
  • Prostate-Specific Antigen