Retrieval of Undeflatable Stent Balloon Using Laser Energy

Cardiovasc Revasc Med. 2021 Jul:28S:136-139. doi: 10.1016/j.carrev.2020.10.024. Epub 2020 Nov 2.

Abstract

Percutaneous coronary intervention (PCI) is one of the most frequent non-surgical procedures performed worldwide. As any invasive procedure, PCI is accompanied by a low but still important risk of complications. One such very rare complication is when the angioplasty balloon cannot be deflated. We present a case of undeflatable balloon during chronic total occlusion PCI and we report a novel technique for balloon retrieval: using the Excimer light amplification by stimulated emission of radiation (Laser) coronary atherectomy device.

Keywords: CTO; Coronary artery disease; Laser; PCI; Undeflatable balloon.

Publication types

  • Case Reports

MeSH terms

  • Angioplasty, Balloon, Coronary* / adverse effects
  • Chronic Disease
  • Coronary Angiography
  • Coronary Occlusion*
  • Humans
  • Lasers, Excimer / adverse effects
  • Percutaneous Coronary Intervention* / adverse effects
  • Stents
  • Treatment Outcome