The Validity and Reliability of Global Positioning System Units for Measuring Distance and Velocity During Linear and Team Sport Simulated Movements

J Strength Cond Res. 2020 Nov;34(11):3070-3077. doi: 10.1519/JSC.0000000000003787.

Abstract

Huggins, RA, Giersch, GEW, Belval, LN, Benjamin, CL, Curtis, RM, Sekiguchi, Y, Peltonen, J, and Casa, DJ. The validity and reliability of GPS units for measuring distance and velocity during linear and team sport simulated movements. J Strength Cond Res 34(11): 3070-3077, 2020-This experimental study aimed to assess the validity and reliability of shirt-mounted 10-Hz global positioning system (GPS) units (Polar Team Pro) for measuring total distance (TD), constant velocity (VelC), and instantaneous velocity (VelI) during linear running and a team sport simulation circuit (TSSC). Fifteen male soccer athletes completed linear tasks (40 and 100 m) at various velocities: walk (W) (4.8-7.9 km·h), jog (J) (8.0-12.7 km·h), run (R) (12.9-19.9 km·h), and sprint (S) (>20.0 km·h) and a 120-m TSSC. Global positioning system validity and reliability for TD, VelC, and VelI were compared with criterion measures using 2 methods (a and b) of GPS raw data extraction. When measuring TD for the Polar Team Pro device, validity and reliability measures were <5% error at all velocities during the 40-m (with the exception of the S [%CV = 8.03]) and 100-m linear trial (both extraction methods) and TSSC. The GPS mean difference (±SD) for TD during the TSSC using extraction methods (a) and (b) was 0.2 ± 1.2 and 2.2 ± 2.2 m, respectively. The validity of the device in measuring VelC was significantly different (p < 0.05) at all velocities during the 40 m (exception W) and the 100 m, with effect sizes ranging from trivial to small (exception of 100 m S). VelI was similar (p > 0.05) at all velocities, except for the W (p = 0.001). The reliability of the device when measuring VelC during the 40 and 100 m was <5% CV; however, during the 100 m, VelI ranged from 1.4 to 12.9%. Despite trivial to large effect sizes for validity of TD, this device demonstrated good reliability <5% CV during linear and TSSC movements. Similarly, effect sizes ranged from trivial to large for VelC, and yet VelI reliability was good for VelC, but good to poor for VelI.

MeSH terms

  • Athletes*
  • Geographic Information Systems / standards*
  • Humans
  • Male
  • Movement
  • Reproducibility of Results
  • Running / physiology
  • Soccer / physiology*
  • Team Sports*
  • Walking / physiology
  • Young Adult