Abstract

Pump-and-treat technology is among the most used technologies for groundwater remediation. While conventional, vertical wells (VRWs) are well-known and used from long time, horizontal wells (HRWs) have been explored for remediation technologies only in last few decades. HRWs have shown to outperform vertical wells in terms of versatility, productivity and clean-up times under certain conditions. In this paper, the efficacy of an innovative pump-and-treat (P&T) configuration for groundwater remediation obtained by adopting either VRWs or HRWs technology is comparatively tested. A 3D transient finite element model of an unconfined aquifer containing a hexavalent chromium (Cr(VI)) contamination plume is considered to compare a single horizontal well configuration vs a range of spatially-optimised arrays containing vertical wells. A sensitivity analysis aimed at finding the best configuration to minimise the remediation time and the related cost is carried out by comparing different well diameters, D, pumping rates, Q, and position of wells. A comparative cost analysis demonstrates that, for the examined case-study, a single HRW achieves the clean-up goals in the same time span as for a greater number of vertical wells, but at higher price due to the excavation costs.

Keywords: Computational fluid dynamic (CFD); Groundwater remediation; Hexavalent chromium; Horizontal wells; Pump and treat.

MeSH terms

  • Chromium / analysis
  • Groundwater*
  • Water Wells

Substances

  • Chromium
  • chromium hexavalent ion