Modulation of Corticospinal Excitability by Two Different Somatosensory Stimulation Patterns; A Pilot Study

Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul:2020:3573-3576. doi: 10.1109/EMBC44109.2020.9175393.

Abstract

Following amputation, almost two-thirds of amputees experience unpleasant to painful sensations in the area of the missing limb. Whereas the mechanism of phantom limb pain (PLP) remains unknown, it has been shown that maladaptive cortical plasticity plays a major role in PLP. Transcutaneous electrical nerve stimulation (TENS) generating sensory input is believed to be beneficial for PLP relief. TENS effect may be caused by possible reversing reorganization at the cortical level that can be evaluated by changes in the excitability of the corticospinal (CS) pathway. Excitability changes are dependent on the chosen stimulation patterns and parameters. The aim of this study was to investigate the effect of two TENS patterns on the excitability of the CS tract among healthy subjects. We compared a non-modulated TENS as a conventional pattern with pulse width modulated TENS pattern. Motor evoked potentials (MEPs) from APB muscles of stimulated arm (TENS-APB) and contralateral arm (Control-APB) were recorded. We applied single TMS pulses on two subjects for each TENS pattern. The results showed that both patterns increase the CS excitability, while the effects of the conventional TENS is stronger. However, the amplitude of MEPs from control-APB after TENS delivery remained almost the same.Clinical Relevance- The primary results revealed changes in the activity of CS pathway for both patterns. A future study on a larger population is needed to provide strong evidence on the changes in CS excitability. The evaluation part with more factors such as changes in intracortical inhibition (ICI) may be beneficial to find an optimal modulated TENS pattern to enhance pain alleviation process in PLP.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Evoked Potentials, Motor
  • Humans
  • Motor Cortex*
  • Pilot Projects
  • Pyramidal Tracts
  • Transcutaneous Electric Nerve Stimulation*