Evaluation of traditional initial vancomycin dosing versus utilizing an electronic AUC/MIC dosing program

Pharm Pract (Granada). 2020 Jul-Sep;18(3):2024. doi: 10.18549/PharmPract.2020.3.2024. Epub 2020 Sep 15.

Abstract

Background: Area under the curve to minimum inhibitory concentration (AUC/MIC) has been recommended by the 2020 updated vancomycin guidelines for dosing vancomycin for both efficacy and safety. Previously, AUC/MIC has been cumbersome to calculate so surrogate trough concentrations of 15-20 mg/dL were utilized. However, trough-based dosing is not a sufficient surrogate as AUC/MIC targets of 400-600 can usually be reached without achieving troughs of 15-20 mg/dL. Targeting higher trough levels may also lead to adverse events including acute kidney injury (AKI) and nephrotoxicity.

Objective: To compare the mean total first day vancomycin dose in traditional trough-based dosing versus dosing recommended by an AUC/MIC dosing program.

Methods: Adult inpatients who received at least 24 hours of IV vancomycin treatment were included in this single-center, retrospective cohort study. The primary endpoint was difference in mean total first day vancomycin dose in milligrams (mg) received between patients' traditional trough-based dosing and recommended dose via AUC/MIC electronic dosing calculator. Patients served as their own control by analyzing both actual dose received and dose recommended by the electronic AUC/MIC program. Rates of vancomycin induced adverse events, including acute kidney injury, elevated steady-state trough concentrations, and Red Man's syndrome were also compared between patients who received doses consistent with the AUC/MIC dosing recommendation versus those who did not.

Results: 264 patients were included in this study. Initial 24-hour vancomycin exposure was significantly lower with the recommended AUC/MIC dose versus the dose received (2380.7; SD 966.6 mg vs 2649.6; SD 831.8 mg, [95% CI 114.7:423.1] p=0.0007).

Conclusions: Utilizing an electronic AUC/MIC vancomycin dosing calculator would result in lower total first day vancomycin doses.

Keywords: Acute Kidney Injury; Area Under Curve; Drug Monitoring; Inpatients; Microbial Sensitivity Tests; Retrospective Studies; Software; United States; Vancomycin.