Inter-rater reliability of paediatric emergency assessment: physiological and clinical features

Arch Dis Child. 2021 Feb;106(2):149-153. doi: 10.1136/archdischild-2019-318664. Epub 2020 Sep 28.

Abstract

Objective: The Paediatric Admission Guidance in the Emergency Department (PAGE) score is an assessment tool currently in development that helps predict hospital admission using components including patient characteristics, vital signs (heart rate, temperature, respiratory rate and oxygen saturation) and clinical features (eg, breathing, behaviour and nurse judgement). It aims to assist in safe admission and discharge decision making in environments such as emergency departments and urgent care centres. Determining the inter-rater reliability of scoring tools such as PAGE can be difficult. The aim of this study was to determine the inter-rater reliability of seven clinical components of the PAGE Score.

Design: Inter-rater reliability was measured by each patient having their clinical components recorded by two separate raters in succession. The first rater was the assessing nurse, and the second rater was a research nurse.

Setting: Two emergency departments and one urgent care centre in the North West of England. Measurements were recorded over 1 week; data were collected for half a day at each of the three sites.

Patients: A convenience sample of 90 paediatric attendees (aged 0-16 years), 30 from each of the three sites.

Main outcome measures: Two independent measures for each child were compared using kappa or prevalence-adjusted bias-adjusted kappa (PABAK). Bland-Altman plots were also constructed for continuous measurements.

Results: Inter-rater reliability ranged from moderate (0.62 (95% CI 0.48 to 0.74) weighted kappa) to very good (0.98 (95% CI 95 to 0.99) weighted kappa) for all measurements except 'nurse judgement' for which agreement was fair (0.30, 95% CI 0.09 to 0.50 PABAK). Complete information from both raters on all the clinical components of the PAGE score were available for 73 children (81%). These total scores showed good' inter-rater reliability (0.64 (95% CI 0.53 to 0.74) weighted kappa).

Conclusions: Our findings suggest different nurses would demonstrate good inter-rater reliability when collecting acute assessments needed for the PAGE score, reinforcing the applicability of the tool. The importance of determining reliability in scoring systems is highlighted and a suitable methodology was presented.

Keywords: accident & emergency; general paediatrics; paediatric practice.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Adolescent
  • Child
  • Child, Preschool
  • Emergencies*
  • Emergency Medical Services / standards*
  • Emergency Service, Hospital
  • England
  • Female
  • Humans
  • Infant
  • Infant, Newborn
  • Male
  • Observer Variation
  • Reproducibility of Results
  • Severity of Illness Index*
  • State Medicine