Role of IgM testing in the diagnosis and post-treatment follow-up of syphilis: a prospective cohort study

BMJ Open. 2020 Sep 21;10(9):e035838. doi: 10.1136/bmjopen-2019-035838.

Abstract

Objectives: The diagnosis of repeat syphilis and its follow-up remains challenging. We aimed to investigate if IgM testing may assist in the diagnosis of syphilis reinfection/relapse and its treatment follow-up.

Methods: This substudy was conducted in the context of a syphilis biomarker discovery study (ClinicalTrials.gov Nr: NCT02059525). Sera were collected from 120 individuals with a new diagnosis of syphilis (72 with repeat infections) and 30 syphilis negative controls during a cohort study investigating syphilis biomarkers conducted at a sexually transmitted infection/HIV clinic in Antwerp, Belgium. Syphilis was diagnosed based on a simultaneous positive treponemal and non-treponemal assay result and/or positive serum PCR targeting polA. Specimens collected at visit of diagnosis, and 3 and 6 months post-treatment were tested by two enzyme immunoassays (EIAs), recomWell (Mikrogen; MI) and Euroimmun (EU), to detect anti-treponemal IgM. Baseline specimens were also tested for anti-treponemal IgM using a line immunoassay (LIA) recomLine (MI). Quantitative kinetic decay curves were constructed from the longitudinal quantitative EIA results.

Results: An overall sensitivity for the diagnosis of syphilis of 59.8% (95% CI: 50.3%-68.7%), 75.0% (95% CI: 66.1%-82.3%) and 63.3% (95% CI: 54.8%-72.6%) was obtained for the EU, MI EIAs and MI LIA, respectively. When only considering repeat syphilis, the diagnostic sensitivity decreased to 45.7% (95% CI: 33.9%-58.0%), 63.9% (95% CI: 51.7%-74.6%) and 47.2% (95% CI: 35.5%-59.3%), respectively. IgM seroreverted in most cases 6 months after treatment. Post-treatment IgM concentrations decreased almost 30% faster for initial syphilis compared with repeat infection. The IgM EIAs and IgM LIA agreed from fairly to moderately (Cohen's kappa (κ): 0.36 (EU EIA); κ: 0.53 (MI EIA); κ: 0.40 (MI LIA)) with the diagnosis of syphilis.

Conclusions: IgM detection was not a sensitive method to diagnose syphilis and was even poorer in the diagnosis of syphilis repeat infections.

Keywords: diagnostic microbiology; microbiology; sexual medicine.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antibodies, Bacterial
  • Belgium
  • Cohort Studies
  • Follow-Up Studies
  • Humans
  • Immunoglobulin M
  • Prospective Studies
  • Sensitivity and Specificity
  • Syphilis Serodiagnosis
  • Syphilis* / diagnosis
  • Syphilis* / drug therapy
  • Treponema pallidum

Substances

  • Antibodies, Bacterial
  • Immunoglobulin M

Associated data

  • ClinicalTrials.gov/NCT02059525