The 'armed concrete' approach: stent-screw-assisted internal fixation (SAIF) reconstructs and internally fixates the most severe osteoporotic vertebral fractures

J Neurointerv Surg. 2021 Jan;13(1):63-68. doi: 10.1136/neurintsurg-2020-016597. Epub 2020 Sep 16.

Abstract

Background: The treatment of severe osteoporotic vertebral compression fractures (VCFs) with middle-column (MC) involvement, high fragmentation, large cleft and/or pedicular fracture is challenging. Minimally invasive 'stent-screw-assisted internal fixation' (SAIF) can reduce the fracture, reconstruct the vertebral body (VB) and fix it to the posterior elements.

Objective: To assess feasibility, safety, technical and clinical outcome of the SAIF technique in patients with severe osteoporotic VCFs.

Methods: 80 treated vertebrae were analyzed retrospectively. Severe VCFs were characterized by advanced collapse (Genant grade 3), a high degree of osseous fragmentation (McCormack grade 2 and 3), burst morphology with MC injury, pediculo-somatic junction fracture, and/or large osteonecrotic cleft. VB reconstruction was evaluated on postprocedure radiographs and CT scans by two independent raters. Clinical and radiological follow-ups were performed at 1 and 6 months.

Results: SAIF was performed at 28 thoracic and 52 lumbar levels in 73 patients. One transient neurological complication occurred. VB reconstruction was satisfactory in 98.8% of levels (inter-rater reliability 96%, κ=1). Follow-up at 1 month was available for 78/80 levels and at 6 months or later (range 6-24, mean 7.9 months) for 73/80 levels. Significant improvement in the Visual Analog Scale score was noted at 1 and 6 months after treatment (p<0.05). Patients reported global clinical benefit during follow-up (Patient's Global Impression of Change Scale 5.6±0.9 at 1 month and 6.1±0.9 at 6 months). Fourteen new painful VCFs occurred at different levels in 11 patients during follow-up, treated with vertebral augmentation or SAIF. Target-level stability was maintained in all cases.

Conclusions: SAIF is a minimally invasive, safe, and effective treatment for patients with severe osteoporotic VCFs with MC involvement.

Keywords: spine; stent; technique.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Screws*
  • Female
  • Follow-Up Studies
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods*
  • Fractures, Compression / diagnostic imaging
  • Fractures, Compression / surgery*
  • Humans
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / surgery
  • Male
  • Middle Aged
  • Osteoporotic Fractures / diagnostic imaging
  • Osteoporotic Fractures / surgery*
  • Plastic Surgery Procedures / instrumentation
  • Plastic Surgery Procedures / methods*
  • Reproducibility of Results
  • Retrospective Studies
  • Spinal Fractures / diagnostic imaging
  • Spinal Fractures / surgery*
  • Stents*
  • Thoracic Vertebrae / diagnostic imaging
  • Thoracic Vertebrae / surgery
  • Treatment Outcome