Image Quality and Reliability of a Novel Dark-Blood Late Gadolinium Enhancement Sequence in Ischemic Cardiomyopathy

J Thorac Imaging. 2020 Sep;35(5):326-333. doi: 10.1097/RTI.0000000000000448.

Abstract

Purpose: The aim of this study was to assess the reliability of a 2D dark-blood phase-sensitive late gadolinium enhancement sequence (2D-DBPSLGE) compared with 2D phase-sensitive inversion recovery late gadolinium enhancement sequence (2D-BBPSLGE) in patients with ischemic cardiomyopathy (ICM).

Materials and methods: A total of 73 patients with a clinical history of ICM were prospectively enrolled. The following endpoints were evaluated: (a) comparison of image quality between 2D-BBPSLGE and 2D-DBPSLGE for differentiation between blood pool-late gadolinium enhancement (LGE), remote myocardium-LGE, and blood pool-remote myocardium; (b) diagnostic accuracy of 2D-DBPSLGE compared with gold standard 2D-BBPSLGE for the evaluation of infarcted segments; (c) diagnostic accuracy of 2D-DBPSLGE for the evaluation of microvascular obstruction (MVO); (d) comparison of transmurality index between 2D-BBPSLGE and 2D-DBPSLGE; (e) comparison of papillary muscle hyperenhancement between 2D-BBPSLGE and 2D-DBPSLGE; inter-reader agreement for depiction of hyperenhanced segments in both LGE sequences. Data were analyzed using paired t test, Wilcoxon test, and McNemar test, and η coefficient and intercorrelation coefficient (ICC).

Results: Image quality was superior for 2D-DBPSLGE for differentiation of blood pool-LGE (P<0.001). 2D-DBPSLGE, compared with 2D-BBPSLGE, showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 96.93%, 99.89%, 99.71%, 98.78, and 99.04%, respectively. Concerning MVO detection, 2D-DBPSLGE showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66.67%, 100.00%, 100.00%, 80.95%, and 86.21%, respectively. 2D-DBPSLGE underestimated the transmurality (P=0.007) and identified papillary muscle hyperenhancement (P<0.001). Both LGE sequences showed comparable interobserver agreement for the evaluation of infarcted areas (2D-BBPSLGE: ICC 0.99;2D-DBPSLGE: ICC 0.99).

Conclusions: Compared with 2D-BBPSLGE, 2D-DBPSLGE sequences provide better differentiation between LGE and blood-pool, while underestimating LGE trasmurality and the presence of MVO.

MeSH terms

  • Cardiomyopathies / complications
  • Cardiomyopathies / diagnostic imaging*
  • Contrast Media*
  • Female
  • Gadolinium*
  • Humans
  • Image Enhancement / methods*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Myocardial Ischemia / complications
  • Myocardial Ischemia / diagnostic imaging*
  • Prospective Studies
  • Reproducibility of Results

Substances

  • Contrast Media
  • Gadolinium