Modeling of a neutron irradiator using Monte Carlo

Appl Radiat Isot. 2020 Nov:165:109332. doi: 10.1016/j.apradiso.2020.109332. Epub 2020 Jul 22.

Abstract

The Nuclear Engineering Department of the Military Institute of Engineering (SE/7-IME) is designing and simulation a neutron irradiator with 1 Ci of 241Am-9Be source. The objective of this irradiator is to generate a flux of neutrons to be used in research and teaching maintaining, for purposes of radiological protection, the rate of ambient dose equivalent, H*(10), below 10 μSv/h at 30 cm from the surface. This paper presents the proposed irradiator, values of H*(10) at different distances from the irradiator and the neutron flux in different points of the beam irradiation, all calculated using the MCNPX code.

Keywords: Ambient dose equivalent; MCNPX code; Neutron irradiator.