Early strategy of scepter XC balloon angioplasty and simultaneous Nimodipine infusion for vasospasm following ruptured aneurysm

BMC Neurol. 2020 Jul 7;20(1):271. doi: 10.1186/s12883-020-01856-4.

Abstract

Background: Cerebral vasospasm still results in high morbidity and mortality rates in patients after aneurysmal subarachnoid hemorrhage (SAH). The aim of this study was to establish a protocol for the management of vasospasm and demonstrate our experience of angioplasty using the Scepter XC balloon catheter.

Methods: In this retrospective study, a computed tomography angiography and perfusion image was arranged if early symptoms occurred or on the 7th day following aneurysmal SAH. In patients with clear consciousness, balloon angioplasties were performed for symptomatic vasospasms, which were not improved within 6-12 h after maximal medical treatments. In unconscious patients, balloon angioplasties were performed for all patients with angiographic vasospasms.

Results: Fifty patients underwent Scepter XC balloon angioplasty among 396 consecutive patients who accepted endovascular or surgical treatments for ruptured aneurysms. All angioplasty procedures were successful without complications. 100% angiographic improvement and 94% clinical improvement were reached immediately after the angioplasties. A favorable functional outcome (modified Rankin Score of ≤2) could be achieved in 82% of patients. Even in patients with poor clinical grading (Hunt-Hess grade 4-5), a clinical improvement rate of 87.5% and favorable outcome rate was 70.8% could be achieved.

Conclusion: Balloon angioplasty with Scepter XC balloon catheter is safe and effective for post-SAH vasospasm. This device's extra-compliant characteristics could considerably improve the quality of angioplasty procedures. For all patients, even those with poor neurological status, early treatment with combined protocol of nimodipine and angioplasty can have good clinical outcomes.

Keywords: Aneurysm rupture; Balloon angioplasty; subarachnoid hemorrhage; Cerebral aneurysm; Scepter XC balloon.

MeSH terms

  • Adult
  • Aged
  • Aneurysm, Ruptured / complications*
  • Angioplasty, Balloon / adverse effects
  • Angioplasty, Balloon / methods
  • Computed Tomography Angiography
  • Female
  • Humans
  • Intracranial Aneurysm / complications*
  • Male
  • Middle Aged
  • Nimodipine / therapeutic use*
  • Retrospective Studies
  • Subarachnoid Hemorrhage / complications
  • Treatment Outcome
  • Vasospasm, Intracranial / etiology*

Substances

  • Nimodipine