Protrusion of a ceramic femoral head through the acetabular metallic cup in total-hip arthroplasty: A case report

Medicine (Baltimore). 2020 Jun 12;99(24):e20469. doi: 10.1097/MD.0000000000020469.

Abstract

Rationale: Dislocation, wear, metallosis, and implant loosening are well-known complications of a failed total-hip arthroplasty (THA), and acetabular liner dissociation is an uncommon but catastrophic complication. To our knowledge, this is the first description of metallosis due to acetabular liner dissociation, but not presenting as a result of wear of a metal-on-metal articulation and a polyethylene liner of other articulation.

Patient concerns: We described a 61-year-old man who had a 2-year history of pain in the right groin region after THA. Postoperative period of primary THA was uneventful. However, he did not undergo postoperative follow-up, and often participated in strenuous sports activities including mountain climbing and long-distance running.

Diagnosis: Radiographs demonstrated superior subluxation of the femoral head and direct articulation and abrasion wear of the ceramic femoral head on the cup. Preoperative laboratory data revealed no signs of infection.

Interventions: We performed revision THA using a direct lateral approach with ceramic-on-ceramic hip prosthesis.

Outcomes: Postoperatively, the patient wore a hip orthosis for 6 weeks to prevent dislocation but was allowed full weight bearing. At 1-year follow-up, there was no recurrence of hip pain.

Lessons: Wear of THA components can result in catastrophic failure of the implants and significant soft-tissue metallosis. Therefore, regular postoperative follow-up is necessary for early intervention, even in those with asymptomatic hips.