Zero-Overlap Fluorophores for Fluorescent Studies at Any Concentration

J Am Chem Soc. 2020 Jul 15;142(28):12167-12180. doi: 10.1021/jacs.0c02450. Epub 2020 Jul 6.

Abstract

Fluorophores are powerful tools for the study of chemistry, biology, and physics. However, fluorescence is severely impaired when concentrations climb above 5 μM as a result of effects like self-absorption and chromatic shifts in the emitted light. Herein, we report the creation of a charge-transfer (CT) fluorophore and the discovery that its emission color seen at low concentrations is unchanged even at 5 mM, some 3 orders of magnitude beyond typical limits. The fluorophore is composed of a triphenylamine-substituted cyanostar macrocycle, and it exhibits a remarkable Stokes shift of 15 000 cm-1 to generate emission at 633 nm. Crucial to the performance of this fluorophore is the observation that its emission spectrum shows near-zero overlap with the absorption band at 325 nm. We propose that reducing the spectral overlap to zero is a key to achieving full fluorescence across all concentrations. The triphenylamine donor and five cyanostilbene acceptor units of the macrocycle generate an emissive CT state. Unlike closely related donor-acceptor control compounds showing dual emission, the cyanostar framework inhibited emission from the second state to create a zero-overlap fluorophore. We demonstrated the use of emission spectroscopy for characterization of host-guest complexation at millimolar concentrations, which are typically the exclusive domain of NMR spectroscopy. The binding of the PF6- anion generates a 2:1 sandwich complex with blue-shifted emission. Distinct from twisted intramolecular charge-transfer (TICT) states, experiment-supported density functional theory shows a 67° twist inside an acceptor unit in the CT state instead of displaying a twist between the donor and acceptor; it is TICT-like. Inspired by the findings, we uncovered similar concentration-independent behavior from a control compound, strongly suggesting this behavior may be latent to other large Stokes-shift fluorophores. We discuss strategies capable of generating zero-overlap fluorophores to enable accurate fluorescence characterization of processes across all practical concentrations.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Density Functional Theory
  • Fluorescent Dyes / analysis*
  • Molecular Structure
  • Spectrometry, Fluorescence

Substances

  • Fluorescent Dyes