Effect of the short-segment internal fixation with intermediate inclined-angle polyaxial screw at the fractured vertebra on the treatment of Denis type B thoracolumbar fracture

J Orthop Surg Res. 2020 May 24;15(1):182. doi: 10.1186/s13018-020-01686-7.

Abstract

Background: Short-segment internal fixation with intermediate straight-forward monoaxial screws (SSIF-SFM) and long-segment internal fixation (LSIF) are the two major surgical options for thoracolumbar (TL) fracture. However, SSIF-SFM might not provide adequate support to the spine, and LSIF is unnecessarily extensive. SSIF with intermediate inclined-angle polyxial screw (SSIF-IAP) might offer an alternative solution for the treatment of TL fracture.

Methods: A retrospective study was conducted. Sixty-nine patients (47 males and 22 females; average 34.5 years) with Denis type B TL fracture who met the criteria for inclusion were enrolled. Sagittal Cobb's angle (SCA), anterior vertebral body height (AVBH), vertebral body index (VBI), and spinal canal encroachment (SCE) were measured and assessed. Visual analogue scale (VAS) and Oswestry disability index (ODI) were also evaluated.

Results: The average values of incision length, blood loss, duration of operation, and hospital stay in the SSIF-IAP group and SSIF-SFM group were significantly decreased compared with those in the LSIF group. The AVBH and VBI in the SSIF-IAP group and LSIF group were significantly improved than those in the SSIF-SFM group at 6-month and the latest follow-ups (P < 0.05). The correction losses of AVBH and VBI (calculated by the reduction of AVBH and VBI) in the SSIF-IAP group and LSIF group were also significantly decreased compared with those in the SSIF-SFM group at 6-month and the latest follow-ups (P < 0.05). There was no significant difference of SCE among the three groups postoperatively. The VAS and ODI in the SSIF-IAP group and SSIF-SFM group were significantly decreased compared with those in the LSIF group at 6-month and the latest follow-ups (P < 0.05).

Conclusion: Both SSIF-IAP and LSIF can improve the biomechanical stability as compared with SSIF-SFM. Moreover, SSIF-IAP was less extensive compared to LSIF. SSIF-IAP was an effective and reliable operative technique for patients with Denis type B TL fracture.

Keywords: Inclined-angle screw placement; Intermediate screw; Long-segment internal fixation; Short-segment internal fixation; Thoracolumbar fracture.

MeSH terms

  • Adult
  • Bone Screws*
  • Female
  • Fracture Fixation, Internal / methods*
  • Fracture Fixation, Internal / trends
  • Humans
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / injuries
  • Lumbar Vertebrae / surgery*
  • Male
  • Middle Aged
  • Retrospective Studies
  • Spinal Fractures / diagnostic imaging
  • Spinal Fractures / surgery*
  • Thoracic Vertebrae / diagnostic imaging
  • Thoracic Vertebrae / injuries
  • Thoracic Vertebrae / surgery*
  • Treatment Outcome
  • Young Adult