Electrospun PLGA Fiber Diameter and Alignment of Tendon Biomimetic Fleece Potentiate Tenogenic Differentiation and Immunomodulatory Function of Amniotic Epithelial Stem Cells

Cells. 2020 May 13;9(5):1207. doi: 10.3390/cells9051207.

Abstract

Injured tendons are challenging in their regeneration; thus, tissue engineering represents a promising solution. This research tests the hypothesis that the response of amniotic epithelial stem cells (AECs) can be modulated by fiber diameter size of tendon biomimetic fleeces. Particularly, the effect of electrospun poly(lactide-co-glycolide) (PLGA) fleeces with highly aligned microfibers possessing two different diameter sizes (1.27 and 2.5 µm: ha1- and ha2-PLGA, respectively) was tested on the ability of AECs to differentiate towards the tenogenic lineage by analyzing tendon related markers (Collagen type I: COL1 protein and mRNA Scleraxis: SCX, Tenomodulin: TNMD and COL1 gene expressions) and to modulate their immunomodulatory properties by investigating the pro- (IL-6 and IL-12) and anti- (IL-4 and IL-10) inflammatory cytokines. It was observed that fiber alignment and not fiber size influenced cell morphology determining the morphological change of AECs from cuboidal to fusiform tenocyte-like shape. Instead, fleece mechanical properties, cell proliferation, tenogenic differentiation, and immunomodulation were regulated by changing the ha-PLGA microfiber diameter size. Specifically, higher DNA quantity and better penetration within the fleece were found on ha2-PLGA, while ha1-PLGA fleeces with small fiber diameter size had better mechanical features and were more effective on AECs trans-differentiation towards the tenogenic lineage by significantly translating more efficiently SCX into the downstream effector TNMD. Moreover, the fiber diameter of 1.27 µm induced higher expression of pro-regenerative, anti-inflammatory interleukins mRNA expression (IL-4 and IL-10) with favorable IL-12/IL-10 ratio with respect to the fiber diameter of 2.5 µm. The obtained results demonstrate that fiber diameter is a key factor to be considered when designing tendon biomimetic fleece for tissue repair and provide new insights into the importance of controlling matrix parameters in enhancing cell differentiation and immunomodulation either for the cells functionalized within or for the transplanted host tissue.

Keywords: PLGA; aligned fibers; amniotic epithelial stem cells; biomimetic scaffold; electrospinning; fiber diameter size; immunomodulation; tendon; tendon tissue engineering; tenogenic differentiation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Amnion / cytology*
  • Animals
  • Anti-Inflammatory Agents / pharmacology
  • Biomimetic Materials / pharmacology*
  • Cell Differentiation / drug effects*
  • Cell Proliferation / drug effects
  • Cell Shape / drug effects
  • Cell Survival / drug effects
  • Epithelial Cells / cytology
  • Epithelial Cells / drug effects
  • Epithelial Cells / metabolism
  • Immunologic Factors / pharmacology*
  • Interleukins / pharmacology
  • Polylactic Acid-Polyglycolic Acid Copolymer / chemistry*
  • Sheep
  • Spectroscopy, Fourier Transform Infrared
  • Stem Cells / cytology
  • Stem Cells / drug effects
  • Stem Cells / immunology*
  • Stem Cells / metabolism
  • Tendons / cytology*
  • Tissue Engineering*

Substances

  • Anti-Inflammatory Agents
  • Immunologic Factors
  • Interleukins
  • Polylactic Acid-Polyglycolic Acid Copolymer