Lower maximum forces on oral structures when using gum-elastic bougie than when using endotracheal tube and stylet during both direct and indirect laryngoscopy by novices: a crossover study using a high-fidelity simulator

BMC Emerg Med. 2020 May 6;20(1):34. doi: 10.1186/s12873-020-00328-9.

Abstract

Background: Applying excessive force during endotracheal intubation (ETI) is associated with several complications, including dental trauma and hemodynamic alterations. A gum-elastic bougie (GEB), a type of tracheal tube introducer, is a useful airway adjunct for patients with poor laryngoscopic views. However, how the use of a GEB affects the force applied during laryngoscopy is unclear. We compared the force applied on the oral structures during ETI performed by novices using the GEB versus an endotracheal tube + stylet.

Methods: This prospective crossover study was conducted from April 2017 to March 2019 in a public medical university in Japan. In total, 209 medical students (4th and 5th grade, mean age of 23.7 ± 2.0 years) without clinical ETI experience were recruited. The participants used either a Macintosh direct laryngoscope (DL) or C-MAC video laryngoscope (VL) in combination with a GEB or stylet to perform ETI on a high-fidelity airway management simulator. The order of the first ETI method was randomized to minimize the learning curve effect. The outcomes of interest were the maximum forces applied on the maxillary incisors and tongue during laryngoscopy. The implanted sensors in the simulator quantified these forces automatically.

Results: The maximum force applied on the maxillary incisors was significantly lower when using a GEB than when using an endotracheal tube + stylet both with the Macintosh DL (39.0 ± 23.3 vs. 47.4 ± 32.6 N, P < 0.001) and C-MAC VL (38.9 ± 18.6 vs. 42.0 ± 22.1 N, P < 0.001). Similarly, the force applied on the tongue was significantly lower when using a GEB than when using an endotracheal tube + stylet both with the Macintosh DL (31.9 ± 20.8 vs. 37.8 ± 22.2 N, P < 0.001) and C-MAC VL (35.2 ± 17.5 vs. 38.4 ± 17.5 N, P < 0.001).

Conclusions: Compared with the use of an endotracheal tube + stylet, the use of a GEB was associated with lower maximum forces on the oral structures during both direct and indirect laryngoscopy performed by novices. Our results suggest the expanded role of a GEB beyond an airway adjunct for difficult airways.

Keywords: Airway-related adverse events; Medical student; Teeth injury; Tracheal tube introducer; Video laryngoscope.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Clinical Competence*
  • Cross-Over Studies
  • Education, Medical, Undergraduate*
  • Female
  • Humans
  • Intubation, Intratracheal / instrumentation*
  • Japan
  • Laryngoscopes
  • Laryngoscopy / methods*
  • Learning Curve
  • Male
  • Manikins
  • Prospective Studies
  • Tongue / injuries*
  • Tooth Injuries / etiology*
  • Video Recording
  • Young Adult