Multicentre Harmonisation of a Six-Colour Flow Cytometry Panel for Naïve/Memory T Cell Immunomonitoring

J Immunol Res. 2020 Apr 12:2020:1938704. doi: 10.1155/2020/1938704. eCollection 2020.

Abstract

Background: Personalised medicine in oncology needs standardised immunological assays. Flow cytometry (FCM) methods represent an essential tool for immunomonitoring, and their harmonisation is crucial to obtain comparable data in multicentre clinical trials. The objective of this study was to design a harmonisation workflow able to address the most effective issues contributing to intra- and interoperator variabilities in a multicentre project.

Methods: The Italian National Institute of Health (Istituto Superiore di Sanità, ISS) managed a multiparametric flow cytometric panel harmonisation among thirteen operators belonging to five clinical and research centres of Lazio region (Italy). The panel was based on a backbone mixture of dried antibodies (anti-CD3, anti-CD4, anti-CD8, anti-CD45RA, and anti-CCR7) to detect naïve/memory T cells, recognised as potential prognostic/predictive immunological biomarkers in cancer immunotherapies. The coordinating centre distributed frozen peripheral blood mononuclear cells (PBMCs) and fresh whole blood (WB) samples from healthy donors, reagents, and Standard Operating Procedures (SOPs) to participants who performed experiments by their own equipment, in order to mimic a real-life scenario. Operators returned raw and locally analysed data to ISS for central analysis and statistical elaboration.

Results: Harmonised and reproducible results were obtained by sharing experimental set-up and procedures along with centralising data analysis, leading to a reduction of cross-centre variability for naïve/memory subset frequencies particularly in the whole blood setting.

Conclusion: Our experimental and analytical working process proved to be suitable for the harmonisation of FCM assays in a multicentre setting, where high-quality data are required to evaluate potential immunological markers, which may contribute to select better therapeutic options.

Publication types

  • Multicenter Study

MeSH terms

  • Biomarkers / blood
  • CD3 Complex / blood
  • CD4-Positive T-Lymphocytes / immunology
  • CD8-Positive T-Lymphocytes / immunology
  • Color / standards
  • Flow Cytometry / methods
  • Flow Cytometry / standards*
  • Humans
  • Immunologic Memory
  • Immunophenotyping / standards*
  • Italy
  • Leukocyte Common Antigens / blood
  • Leukocytes, Mononuclear / immunology
  • Observer Variation
  • Receptors, CCR7 / blood
  • T-Lymphocyte Subsets / classification*
  • T-Lymphocyte Subsets / immunology

Substances

  • Biomarkers
  • CCR7 protein, human
  • CD3 Complex
  • Receptors, CCR7
  • Leukocyte Common Antigens