Fluorescence-guided imaging for resection margin evaluation in head and neck cancer patients using cetuximab-800CW: A quantitative dose-escalation study

Theranostics. 2020 Mar 4;10(9):3994-4005. doi: 10.7150/thno.43227. eCollection 2020.

Abstract

Tumor-positive resection margins are present in up to 23% of head and neck cancer (HNC) surgeries, as intraoperative techniques for real-time evaluation of the resection margins are lacking. In this study, we investigated the safety and potential clinical value of fluorescence-guided imaging (FGI) for resection margin evaluation in HNC patients. We determined the optimal cetuximab-800CW dose by quantification of intrinsic fluorescence values using multi-diameter single-fiber reflectance, single-fiber fluorescence (MDSFR/SFF) spectroscopy. Methods: Five cohorts of three HNC patients received cetuximab-800CW systemically: three single dose cohorts (10, 25, 50 mg) and two cohorts pre-dosed with 75 mg unlabeled cetuximab (15 or 25 mg). Fluorescence visualization and MDSFR/SFF spectroscopy quantification was performed and were correlated to histopathology. Results: There were no study-related adverse events higher than Common Terminology Criteria for Adverse Events grade-II. Quantification of intrinsic fluorescence values showed a dose-dependent increase in background fluorescence in the single dose cohorts (p<0.001, p<0.001), which remained consistently low in the pre-dosed cohorts (p=0.6808). Resection margin status was evaluated with a sensitivity of 100% (4/4 tumor-positive margins) and specificity of 91% (10/11 tumor-negative margins). Conclusion: A pre-dose of 75 mg unlabeled cetuximab followed by 15 mg cetuximab-800CW was considered the optimal dose based on safety, fluorescence visualization and quantification of intrinsic fluorescence values. We were able to use a lower dose cetuximab-800CW than previously described, while remaining a high sensitivity for tumor detection due to application of equipment optimized for IRDye800CW detection, which was validated by quantification of intrinsic fluorescence values.

Keywords: MDSFR/SFF spectroscopy; cetuximab-800CW; fluorescence-guided imaging; head and neck cancer; intrinsic fluorescence.

Publication types

  • Clinical Trial, Phase I
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Antineoplastic Agents, Immunological / administration & dosage*
  • Benzenesulfonates / administration & dosage*
  • Cetuximab / administration & dosage*
  • Cohort Studies
  • Female
  • Fluorescent Dyes / chemistry
  • Head and Neck Neoplasms / surgery*
  • Humans
  • Indoles / administration & dosage*
  • Male
  • Margins of Excision
  • Middle Aged
  • Optical Imaging*
  • Surgery, Computer-Assisted*

Substances

  • Antineoplastic Agents, Immunological
  • Benzenesulfonates
  • Fluorescent Dyes
  • IRDye 800CW
  • Indoles
  • Cetuximab