The paper presents the procedure for planning an experiment to create standard sets of reagents for a technetium-99m generator based on glucose derivatives. All stages are presented from researching the required quantities of a substance, a reducing agent, a stabilizer and auxiliary components to developing lyophilized kits and conducting quality control. The radiochemical purity of radiopharmaceuticals prepared on the basis of the developed kits ranged from 90.0 to 99.0%. We also showed the functional suitability of the developed preparations on C57B1/6j mice with an implanted malignant tumor - Lewis lung carcinoma.