Shear-unlimited common-path speckle interferometer

Opt Lett. 2020 Mar 15;45(6):1305-1308. doi: 10.1364/OL.382893.

Abstract

A single-aperture common-path speckle interferometer with an unlimited shear amount is developed. This unlimited shear amount is introduced when a Wollaston prism is placed near the Fourier plane of a common-path interferometer, which is built by using a quasi-${4f}$4f imaging system. The fundamentals of the shear amount and the spatial carrier frequency generation are analyzed mathematically, and the theoretical predictions are validated by a static experiment. Mode-I fracture experiments through the three-point bending are conducted to prove the feasibility and the capability of this method in full-field strain measurement with various shear amounts. A remarkable feature of this setup is that no tilt is required between the optical components to produce the unlimited shear amount in off-axis holography.