Development and validation of a UPLC-MS/MS assay for the determination of gemcitabine and its L-carnitine ester derivative in rat plasma and its application in oral pharmacokinetics

Asian J Pharm Sci. 2017 Sep;12(5):478-485. doi: 10.1016/j.ajps.2017.01.001. Epub 2017 Jan 9.

Abstract

A simple and rapid UPLC-MS/MS method to simultaneously determine gemcitabine and its L-carnitine ester derivative (2'-deoxy-2', 2'-difluoro-N-((4-amino-4-oxobutanoyl) oxy)-4-(trimethyl amm-onio) butanoate-cytidine, JDR) in rat plasma was developed and validated. The conventional plasma sample preparation method of nucleoside analogues is solid-phase extraction (SPE) which is time-consuming and cost-expensive. In this study, gradient elution with small particles size solid phase was applied to effectively separate gemcitabine and JDR, and protein precipitation pretreatment was adopted to remove plasma protein and extract the analytes with high recovery(>81%). Method validation was performed as per the FDA guidelines, and the standard curves were found to be linear in the range of 5-4000 ng/ml for JDR and 4-4000 ng/ml for gemcitabine, respectively. The lower limit of quantitation (LLOQ) of gemcitabine and JDR was 4 and 5 ng/ml, respectively. The intra-day and inter-day precision and accuracy results were within the acceptable limits. Finally, the developed method was successfully applied to investigate the pharmacokinetic studies of JDR and gemcitabine after oral administration to rats.

Keywords: ESI, electrospray ionization; Gemcitabine; IS, internal standard; JDR, 2'-deoxy-2', 2'-difluoro-N-((4-amino-4-oxobutanoyl)oxy)-4-(trimethyl amm-onio) butanoate-cytidine; L-carnitine; LLOQ, lower limit of quantification; OCTN2, organic cation/carnitine transporters 2; PK, pharmacokinetic; Pharmacokinetics; Prodrug; QC, quality control; SPE, solid-phase extraction; THU, Tetrahydrouridine; UPLC/MS/MS.