Effects of the LASIK flap thickness on corneal biomechanical behavior: a finite element analysis

BMC Ophthalmol. 2020 Feb 24;20(1):67. doi: 10.1186/s12886-020-01338-8.

Abstract

Background: It is well known that the biomechanical properties change after LASIK refractive surgery. One reason is the impact of flap creation on the residual stroma. The results have revealed that the change is closely related with the flap thickness in several studies. However, the quantitative relationships between the distributions of displacement and stress on the corneal surface and flap thickness have not been studied. The aim of the study was to quantify evaluate the biomechanical change caused by the LASIK flap.

Methods: By building a finite element model of the cornea, the displacement, the stress and the strain on the corneal surface were analyzed.

Results: The results showed that the corneal flap could obviously cause the deformation of the anterior corneal surface. For example, the displacement of the corneal vertex achieved 15 μm more than that without corneal flap, when the thickness of corneal flap was 120 μm thick. This displacement was enough to cause the change of aberrations in the human eyes. In the central part of the cornea, the stress on the anterior corneal surface increased with flap thickness. But the change in the stress on the posterior corneal surface was significantly less than that on the anterior surface. In addition, the stress in the central part of the anterior corneal surface increased significantly as the intra-ocular pressure (IOP) increase. Furthermore the increase of IOP had a clearly less effect on stress distribution at the edge of the cornea. Distributions of strain on the corneal surface were similar to those of stress.

Conclusions: The changes in the biomechanical properties of cornea after refractive surgery should not be ignored.

Keywords: Biomechanical change; Displacement; Finite element model; LASIK flap; Stress.

MeSH terms

  • Biomechanical Phenomena
  • Computer Simulation
  • Cornea / physiopathology*
  • Corneal Topography
  • Elasticity / physiology*
  • Finite Element Analysis*
  • Humans
  • Intraocular Pressure / physiology
  • Keratomileusis, Laser In Situ / methods*
  • Lasers, Excimer / therapeutic use*
  • Models, Theoretical
  • Refraction, Ocular
  • Stress, Mechanical
  • Surgical Flaps / pathology*