Clinical feasibility and safety of transoesophageal motor-evoked potential monitoring

Eur J Cardiothorac Surg. 2020 Jun 1;57(6):1076-1082. doi: 10.1093/ejcts/ezaa002.

Abstract

Objectives: Canine experiments have shown that transoesophageal motor-evoked potential monitoring is feasible, safe and stable, with a quicker response to ischaemia and a better prognostic value than transcranial motor-evoked potentials. We aimed to elucidate whether or not these findings were clinically reproducible.

Methods: A bipolar oesophageal electrode mounted on a large-diameter silicon tube and a train of 5 biphasic wave stimuli were used for transoesophageal stimulation. Results of 18 patients (median age 74.5 years, 13 males) were analysed.

Results: There were no mortalities, spinal cord injuries or complications related with transoesophageal stimulation. Transcranial motor-evoked potential could not be monitored up to the end of surgery in 3 patients for unknown reasons, 2 of whom from the beginning. Transoesophageal motor-evoked potential became non-evocable after manipulation of a transoesophageal echo probe in 2 patients. Strenuous movement of the upper limbs during transoesophageal stimulation was observed in 3 patients. In 14 patients who successfully completed both monitoring methods up to the end of surgery (11 thoraco-abdominal and 3 descending aortic repair), the final results were judged as false positives in 6 by transcranial stimulation and in 1 by transoesophageal stimulation. The stimulation intensity was significantly lower and the upper limb amplitude was significantly higher by transoesophageal stimulation, while the lower limb amplitude was comparable.

Conclusions: Transoesophageal motor-evoked potential monitoring is clinically feasible and safe with a low false positive rate. A better electrode design is required to avoid its migration by transoesophageal echo manipulation. Further studies may be warranted.

Clinical registration number: UMIN000022320.

Keywords: Aortic surgery; Motor-evoked potentials; Spinal cord ischaemia; Transoesophageal stimulation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Animals
  • Dogs
  • Esophagus
  • Evoked Potentials, Motor
  • Feasibility Studies
  • Humans
  • Male
  • Monitoring, Intraoperative*
  • Spinal Cord Injuries*