Pit and fissure sealants penetration capacity and their correlation with fissure morphology

Med Pharm Rep. 2019 Dec;92(Suppl No 3):S50-S54. doi: 10.15386/mpr-1517. Epub 2019 Dec 15.

Abstract

Background and aims: Pit and fissure sealant placement corresponds to an effective approach of the prevention of caries on occlusal surfaces. Fissure morphology and dental material characteristics are the key factors for sealant effectiveness. The aim of this in vitro study was to compare the penetration ability of two commercially available pit and fissure sealants.

Methods: Twenty sound human premolars extracted for orthodontic purpose have been sealed according to manufacturer's instructions as follows: Group I (n=10), light-cured unfilled resin-based sealant, Admira Seal® (Voco GmbH); Group II (n=10), resin modified glass ionomer sealant without varnish, GC Fuji Triage® (GC Corporation). The teeth have been sectioned buccal-lingually in the middle of the occlusal surface, and the sections were examined at 40× with an inverted microscope.

Results: Penetration of the sealants was found to be greater in U-type fissure pattern (91.69%) followed by V-type (75.42%), IK-type (71.24%) and then in I-type (63.98%). The depth of penetration of GC Fuji Triage® (82.85%) demonstrated to be superior to Admira Seal® (76.28%).

Conclusion: U fissure design was more common than other fissure patterns and showed significantly higher penetration for the two type of sealants evaluated. Resin modified glass ionomer sealant used in the present study perform comparably with the filled resin sealant.

Keywords: dental sealant; fissure patterns; penetration.