The German Aerospace Center M-42 radiation detector-A new development for applications in mixed radiation fields

Rev Sci Instrum. 2019 Dec 1;90(12):125115. doi: 10.1063/1.5122301.

Abstract

In the last few years, the Biophysics Working Group of the Institute of Aerospace Medicine of the German Aerospace Center (DLR) started the development of a small low power consumption radiation detector system for the measurement of the absorbed dose to be applied in various environments, such as onboard aircraft, in space, and also as a demonstration tool for students. These so called DLR M-42 detectors are based on an electronics design, which can easily be adjusted to the user- and mission-requirements. M-42 systems were already applied for measurements in airplanes, during two MAPHEUS (Materialphysikalische Experimente unter Schwerelosigkeit) rocket missions, and are currently prepared for long term balloon experiments. In addition, they will be part of the dosimetry suite of the upcoming Matroshka AstroRad Radiation Experiment on the NASA Artemis I mission. This paper gives an overview of the design and the testing of the DLR M-42 systems and provides highlighted results from the MAPHEUS campaigns where the detectors were tested for the first time under space flight conditions. Results clearly show that the system design enables independent measurements starting upon rocket launch due to the built-in accelerometer sensors and provides data for the relevant 6 min of μ-gravity as given for the MAPHEUS missions. These 6 min of the μ-gravity environment at altitudes between 100 and 240 km lead to a total absorbed dose of 1.21 ± 0.15 µGy being equivalent to half a day of radiation background measured with the M-42 in the laboratory at DLR, Cologne, Germany.