Development of Rheumatoid Arthritis Classification from Electronic Image Sensor Using Ensemble Method

Sensors (Basel). 2019 Dec 27;20(1):167. doi: 10.3390/s20010167.

Abstract

Rheumatoid arthritis (RA) is an autoimmune illness that impacts the musculoskeletal system by causing chronic, inflammatory, and systemic effects. The disease often becomes progressive and reduces physical function, causes suffering, fatigue, and articular damage. Over a long period of time, RA causes harm to the bone and cartilage of the joints, weakens the joints' muscles and tendons, eventually causing joint destruction. Sensors such as accelerometer, wearable sensors, and thermal infrared camera sensor are widely used to gather data for RA. In this paper, the classification of medical disorders based on RA and orthopaedics datasets using Ensemble methods are discussed. The RA dataset was gathered from the analysis of white blood cell classification using features extracted from the image of lymphocytes acquired from a digital microscope with an electronic image sensor. The orthopaedic dataset is a benchmark dataset for this study, as it posed a similar classification problem with several numerical features. Three ensemble algorithms such as bagging, Adaboost, and random subspace were used in the study. These ensemble classifiers use k-NN (K-nearest neighbours) and Random forest (RF) as the base learners of the ensemble classifiers. The data classification is accessed using holdout and 10-fold cross-validation evaluation methods. The assessment was based on set of performance measures such as precision, recall, F-measure, and receiver operating characteristic (ROC) curve. The performance was also measured based on the comparison of the overall classification accuracy rate between different ensembles classifiers and the base learners. Overall, it was found that for Dataset 1, random subspace classifier with k-NN shows the best results in terms of overall accuracy rate of 97.50% and for Dataset 2, bagging-RF shows the highest overall accuracy rate of 94.84% over different ensemble classifiers. The findings indicate that the efficiency of the base classifiers with ensemble classifier have substantially improved.

Keywords: classification; ensemble method; image sensor; machine learning; medical datasets; wearable sensor.

MeSH terms

  • Algorithms*
  • Area Under Curve
  • Arthritis, Rheumatoid / classification*
  • Arthritis, Rheumatoid / diagnostic imaging*
  • Electronics, Medical*
  • Image Processing, Computer-Assisted*
  • ROC Curve
  • Reproducibility of Results