Cough maneuver is superior to Valsalva maneuver for detecting mild-extent right-to-left shunt

Scand Cardiovasc J. 2020 Feb;54(1):32-36. doi: 10.1080/14017431.2019.1694172. Epub 2019 Nov 28.

Abstract

Objective: The purpose of this study was to explore the different provocative maneuvers in detecting right-to-left shunt during contrast transthoracic echocardiography (cTTE). Methods: We evaluated 378 patients for right-to-left shunt detection by cTTE at the quiet respiration, during Valsalva maneuver (blowing into a face mask connected to a sphygmomanometer at 40 mmHg for 10 s), and during cough maneuver, performed in random order, and the degree of right-to-left shunt as the number of microbubbles in the left atrium per frame after each provocative maneuver was recorded. Results: The detection rates of right-to-left shunt for quiet respiration, Valsalva maneuver, and cough maneuver were 16%, 33%, and 38%, respectively (p < .001). The detection rate for cough maneuver was significantly higher than that for Valsalva maneuver (p < .001). There was no significant difference between Valsalva maneuver and cough maneuver in terms of detecting moderate- or severe-extent right-to-left shunt (p > .05), but cough maneuver was significantly better than Valsalva maneuver at detecting mild-extent right-to-left shunt (p = .001). Conclusions: Cough maneuver is an effective alternative to Valsalva maneuver, with a higher detection rate for mild-extent right-to-left shunt during cTTE, maybe due to its own mechanical characteristics.

Keywords: Quiet respiration; Valsalva maneuver; contrast transthoracic echocardiography; cough maneuver; right-to-left shunt.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media / administration & dosage
  • Cough*
  • Echocardiography*
  • Female
  • Foramen Ovale, Patent / complications
  • Foramen Ovale, Patent / diagnostic imaging*
  • Foramen Ovale, Patent / physiopathology
  • Hemodynamics*
  • Humans
  • Male
  • Microbubbles
  • Middle Aged
  • Predictive Value of Tests
  • Prognosis
  • Reproducibility of Results
  • Valsalva Maneuver*
  • Young Adult

Substances

  • Contrast Media