Statement of problem: Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed.
Purpose: The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns.
Material and methods: Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other half with resin-modified ceramic crowns (RMC group) bonded with dual-polymerized resin cement onto titanium abutments. The biomechanical state of the restorations and implants was analyzed.
Results: Mean peri-implant bone loss after 5 years of functional life was 0.3 ±0.6 mm. The implant clinical survival rate was 98%. RMC crowns had a survival rate of 70%, whereas MC crowns had a 100% survival rate. RMC crowns had more mechanical complications than the MC group (P<.001). Peri-implant bone loss showed no significant differences between crown type (P=.175).
Conclusions: All peri-implant bone loss values were within the range considered acceptable. Metal-ceramic crowns showed better mechanical behavior than resin-modified ceramic crowns. Biological responses of peri-implant tissue would appear to be independent of the type of cemented crown.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.