Stability-indicating RP-HPLC method development and validation for determination of nine impurities in apixaban tablet dosage forms. Robustness study by quality by design approach

Biomed Chromatogr. 2020 Jan;34(1):e4719. doi: 10.1002/bmc.4719. Epub 2019 Nov 19.

Abstract

A quality by design (QbD) based high-resolution HPLC method is described for determination of impurities in apixaban (APX) in the tablet dosage form. Employing a simple and stability-indicating HPLC method, nine known impurities were quantified with good peak resolution. Mobile phase A (MP-A) was prepared with buffer and acetonitrile 90:10 v/v, while mobile phase B (MP-B) contained water and acetonitrile 10:90 v/v. The gradient program was 0 min, MP-A 75%, B 25%; 20 min, MP-A 65%, B 35%; 30 min, MP-A 40%, B 60%; 40min, MP-A 40%, B 60%; 42 min, MP-A 75%, B 25%; and 50 min, MP-A 75%, B 25%. The chromatographic separation was achieved using a Zorbax RX C18 250 × 4.6 mm column, 5 μm (1.0 ml min-1 , 280 nm, 50 μl) and a column temperature of 40°C. Several separation studies were carried out using design of experiments to optimize the method. Validation results confirm the applicability of the developed method for quality analysis and stability studies of the regular product on the manufacturing stream.

Keywords: RP-HPLC; apixaban; impurities; method development; quality by design; validation.

MeSH terms

  • Chromatography, High Pressure Liquid / methods*
  • Chromatography, Reverse-Phase / methods*
  • Drug Contamination*
  • Drug Stability
  • Limit of Detection
  • Linear Models
  • Pyrazoles / analysis*
  • Pyrazoles / chemistry*
  • Pyridones / analysis*
  • Pyridones / chemistry*
  • Reproducibility of Results
  • Tablets

Substances

  • Pyrazoles
  • Pyridones
  • Tablets
  • apixaban