Enhanced Capabilities of TROPOMI NO2: Estimating NOX from North American Cities and Power Plants

Environ Sci Technol. 2019 Nov 5;53(21):12594-12601. doi: 10.1021/acs.est.9b04488. Epub 2019 Oct 25.

Abstract

The TROPOspheric Monitoring Instrument (TROPOMI) is used to derive top-down NOX emissions for two large power plants and three megacities in North America. We first re-process the vertical column NO2 with an improved air mass factor to correct for a known systematic low bias in the operational retrieval near urban centers. For the two power plants, top-down NOX emissions agree to within 10% of the emissions reported by the power plants. We then derive top-down NOX emissions rates for New York City, Chicago, and Toronto, and compare them to projected bottom-up emissions inventories. In this analysis of 2018 NOX emissions, we find a +22% overestimate for New York City, a -21% underestimate in Toronto, and good agreement in Chicago in the projected bottom-up inventories when compared to the top-down emissions. Top-down NOX emissions also capture intraseasonal variability, such as the weekday versus weekend effect (emissions are +45% larger on weekdays versus weekends in Chicago). Finally, we demonstrate the enhanced capabilities of TROPOMI, which allow us to derive a NOX emissions rate for Chicago using a single overpass on July 7, 2018. The large signal-to-noise ratio of TROPOMI is well-suited for estimating NOX emissions from relatively small sources and for sub-seasonal timeframes.

MeSH terms

  • Air Pollutants*
  • Chicago
  • Cities
  • Environmental Monitoring
  • New York City
  • North America
  • Power Plants
  • United States

Substances

  • Air Pollutants